» Lautsprecher-Systeme  » NeodymLine 100V/WP/54-24

 ITEC NEODYMLINE 4/100V/WP/54-24

 Enviromental Type:   B 
 Termination   Inside screw terminal 
 Rated Noise Voltage:   100V 
 Rated Noise Power:   50 W 
 Power Setting:   50 / 25 / 12,5 / 6,25 W 
 Driver:   4 x 3“ cone neodymium 
 Weight   3,7 kg 
 Dimensions (WxHxD):   100 x 602 x 100 mm 
 IP-rating  min 33 
 Material/Color   welded aluminium / powder coated RAL
 9010, RAL 9011 or customized 
 Mounting   powder coated rigid bracket /
 swing and tilt bracket 
 Sensitivity for the stated
 reference axis: 
 79 dB (Pink noise total 1W/4 Meters) 
 Maximum sound
 pressure level: 
 95 dB (Pink noise total 50W/4 Meters) 



- 2-way high-power column loudspeaker system loaded with 4x3“ neodymium transducers
- passive crossover network unit
- Highest sound pressures even at very small dimensions
- Perfect sound in acoustically challenging areas
- Perfect speech intelligibility in reverberant room
- Integrated power switch (50 / 25 / 12,5 / 6,25 W)
 




The ITEC NeodymLine 4 is a 2-way high-power passive column loudspeaker system with best performance in respect of speech intelligibility and music reproduction in difficult conditions.
Due to the placement of the 4x3“ nodymium transducers and frequency crossover, the vertical pattern is perfect even for reverberant rooms - less reflections onto ceilings.
Developed for areas of public life, where security is the highest bid Certified quality assurance ensuring consistent performance at continuous operation for decades. The optical integration of the NeodymLine - Series is very simply, because of the slim and elegant design. The build in 50 VA Tranformer provides high quality audio performance.

Fields of application: airports, railway stations, malls, industrial buildings, architetural buildings (glass), house of worship, conference rooms, historical building, etc.


 


 Acoustical measurement enviroment:  free field  

Frequency response for each stated reference axis:
(Sensitivity 100Hz-10kHz 1/3 Oct. Pink noise total 1W/4 Meters) 
frequency  dB  frequency  dB  frequency  dB 
100 Hz  55  125 Hz  54  160 Hz  64 
200 Hz 61 250 Hz  66  315  67 
400 Hz 69 500 Hz  66  630  66 
800 Hz 63  1000 Hz  67  1250  67 
1600 Hz 65  2000 Hz  66  2500  65 
3150 Hz 65  4000 Hz  63  5000  63 
6300 Hz 64  8000 Hz  66  10000  67 
           
Horizontal / Vertical coverage angles: 
frequency  horizontal  vertical       
500 Hz 360  142       
1 kHz  198  113       
2 kHz 169  34       
4 kHz 201  22       
           
Rated impedance for each tapping: 
Power  Impedance         
50 W 200 Ω         
25 W 400 Ω         
12,5 W 800 Ω         
6,25 W 1600 Ω         

 
 
Mounting accessories Terminal
Mounting bracket standard (short)
Dimensions:
9 x 6.5 cm
Terminal (standard) Connection terminal covered by metal plate (Ceramic Terminal + thermal fuse) incl. cable entry clamp with stress relief 
Mounting bracket long (optional)
Allows greater tilt of the sound column; Dimensions:
18.5 x 13.5 cm
  Ceramic terminal
(optional)
 
Swing & tilt mounting (optional)
black/white 
   

 




Installation, Operation, Maintenance
To avoid injury or damage, always make sure to mount the speakers securely.
Make sure that all amplifiers are switched of and all controls are turned down before connecting the speaker systems.
Please pay attention on the connection to the transformer board and make sure that the polarity of the speakers is correct (also at the amplifier).
After connecting all systems cross-check the wiring with a phase checker. Make sure that the rated sum power of the speakers do not exceed the output power of the 100 V amplifier!
Do not open the loudspeaker during operation.

Fix the rigid or swing and tilt bracket onto wanted position.
Unscrew the 4 fixing screws of the speaker grille, on the top and bottom lid and remove the grille.
Remove the metal plate, which is covering the connection terminal (2 screws).
Lead cable trough the cable gland and connect to terminal (50/25/12,5/6,25 W).
Fasten the connection terminal cover and fix the speaker with two M6 scews into the thread inserts. Screw in the 4 fixing scews for the speaker grille.
For optimum performance, always use the correct voltage, power and operate within the frequency limits as specified.




 ITEC NEODYMLINE 8/100V/WP/54-24

 Enviromental Type:   B 
 Termination   Inside screw terminal 
 Rated Noise Voltage:   100V 
 Rated Noise Power:   50 W 
 Power Setting:   50 / 25 / 12,5 / 6,25 W 
 Driver:   8 x 3“ cone neodymium 
 Weight   5,4 kg 
 Dimensions (WxHxD):   100 x 967 x 100 mm 
 IP-rating  min 33 
 Material/Color   welded aluminium / powder coated RAL
 9010, RAL 9011 or customized 
 Mounting   powder coated rigid bracket /
 swing and tilt bracket 
 Sensitivity for the stated
 reference axis: 
 81 dB (Pink noise total 1W/4 Meters) 
 Maximum sound
 pressure level: 
 98 dB (Pink noise total 50W/4 Meters) 



- 2-way high-power column loudspeaker system loaded with 8x3“ neodymium transducers
- passive crossover network unit
- Highest sound pressures even at very small dimensions
- Perfect sound in acoustically challenging areas
- Perfect speech intelligibility in reverberant room
- Integrated power switch (50 / 25 / 12,5 / 6,25 W)
 




The ITEC NeodymLine 8 is a 2-way high-power passive column loudspeaker system with best performance in respect of speech intelligibility and music reproduction in difficult conditions.
Due to the placement of the 8x3“ nodymium transducers and frequency crossover, the vertical pattern is perfect even for reverberant rooms - less reflections onto ceilings.
Developed for areas of public life, where security is the highest bid Certified quality assurance ensuring consistent performance at continuous operation for decades. The optical integration of the NeodymLine - Series is very simply, because of the slim and elegant design. The build in 50 VA Tranformer provides high quality audio performance.

Fields of application: airports, railway stations, malls, industrial buildings, architetural buildings (glass), house of worship, conference rooms, historical building, etc.


 


 Acoustical measurement enviroment:  free field  

Frequency response for each stated reference axis:
(Sensitivity 100Hz-10kHz 1/3 Oct. Pink noise total 1W/4 Meters) 
frequency  dB  frequency  dB  frequency  dB 
100 Hz  59  125 Hz  57  160 Hz  67 
200 Hz 65 250 Hz  70  315  70 
400 Hz 70 500 Hz  69  630  66 
800 Hz 68  1000 Hz  69  1250  68 
1600 Hz 68  2000 Hz  69  2500  69 
3150 Hz 67  4000 Hz  66  5000  63 
6300 Hz 64  8000 Hz  66  10000  67 
           
Horizontal / Vertical coverage angles: 
frequency  horizontal  vertical       
500 Hz 360  71       
1 kHz  316  47       
2 kHz 168  28       
4 kHz 185  16       
           
Rated impedance for each tapping: 
Power  Impedance         
50 W 200 Ω         
25 W 400 Ω         
12,5 W 800 Ω         
6,25 W 1600 Ω         

 
 
Mounting accessories Terminal
Mounting bracket standard (short)
Dimensions:
9 x 6.5 cm
Terminal (standard) Connection terminal covered by metal plate (Ceramic Terminal + thermal fuse) incl. cable entry clamp with stress relief 
Mounting bracket long (optional)
Allows greater tilt of the sound column; Dimensions:
18.5 x 13.5 cm
  Ceramic terminal
(optional)
 
Swing & tilt mounting (optional)
black/white 
   

 




Installation, Operation, Maintenance
To avoid injury or damage, always make sure to mount the speakers securely.
Make sure that all amplifiers are switched of and all controls are turned down before connecting the speaker systems.
Please pay attention on the connection to the transformer board and make sure that the polarity of the speakers is correct (also at the amplifier).
After connecting all systems cross-check the wiring with a phase checker. Make sure that the rated sum power of the speakers do not exceed the output power of the 100 V amplifier!
Do not open the loudspeaker during operation.

Fix the rigid or swing and tilt bracket onto wanted position.
Unscrew the 4 fixing screws of the speaker grille, on the top and bottom lid and remove the grille.
Remove the metal plate, which is covering the connection terminal (2 screws).
Lead cable trough the cable gland and connect to terminal (50/25/12,5/6,25 W).
Fasten the connection terminal cover and fix the speaker with two M6 scews into the thread inserts. Screw in the 4 fixing scews for the speaker grille.
For optimum performance, always use the correct voltage, power and operate within the frequency limits as specified.



 ITEC NEODYMLINE 16/100V/WP/54-24

 Enviromental Type:   B 
 Termination   Inside screw terminal 
 Rated Noise Voltage:   100V 
 Rated Noise Power:   100 W 
 Power Setting:   100 / 25 / 12,5 / 6,25 W 
 Driver:   16 x 3“ cone neodymium 
 Weight   10,8 kg 
 Dimensions (WxHxD):   100 x 1918 x 100 mm 
 IP-rating  min 33 
 Material/Color </td>  welded aluminium / powder coated RAL
 9010, RAL 9011 or customized 
 Mounting   powder coated rigid bracket /
 swing and tilt bracket 
 Sensitivity for the stated
 reference axis: 
 82 dB (Pink noise total 1W/4 Meters) 
 Maximum sound
 pressure level: 
 101 dB (Pink noise total 50W/4 Meters) 



- 4-way high-power column loudspeaker system loaded with 16x3“ neodymium transducers
- passive crossover network unit
- Highest sound pressures even at very small dimensions
- Perfect sound in acoustically challenging areas
- Perfect speech intelligibility in reverberant room
- Integrated power switch (100 / 50 / 25 / 12,5 W)
 




The ITEC NeodymLine 16 is a 4-way high-power passive column loudspeaker system with best performance in respect of speech intelligibility and music reproduction in difficult conditions.
Due to the placement of the 16x3“ nodymium transducers and frequency crossover, the vertical pattern is perfect even for reverberant rooms - less reflections onto ceilings.
Developed for areas of public life, where security is the highest bid Certified quality assurance ensuring consistent performance at continuous operation for decades. The optical integration of the NeodymLine - Series is very simply, because of the slim and elegant design. The build in 100 VA Tranformer provides high quality audio performance.

Fields of application: airports, railway stations, malls, industrial buildings, architetural buildings (glass), house of worship, conference rooms, historical building, etc.


 


 Acoustical measurement enviroment:  free field  

Frequency response for each stated reference axis:
(Sensitivity 100Hz-10kHz 1/3 Oct. Pink noise total 1W/4 Meters) 
frequency  dB  frequency  dB  frequency  dB 
100 Hz  61  125 Hz  60  160 Hz  66 
200 Hz 64 250 Hz  70  315  72 
400 Hz 77 500 Hz  71  630  69 
800 Hz 68  1000 Hz  71  1250  70 
1600 Hz 70  2000 Hz  70  2500  70 
3150 Hz 67  4000 Hz  65  5000 < 62 
6300 Hz 64  8000 Hz  66  10000  66 
           
Horizontal / Vertical coverage angles: 
frequency  horizontal  vertical       
500 Hz 360  92       
1 kHz  314  41       
2 kHz 145  23       
4 kHz 179  18       
           
Rated impedance for each tapping: 
Power  Impedance         
100 W 100 Ω         
50 W 200 Ω         
25 W 400 Ω         
12,5 W 800 Ω         

 
 
Mounting accessories Terminal
Mounting bracket standard (short)
Dimensions:
9 x 6.5 cm
Terminal (standard) Connection terminal covered by metal plate (Ceramic Terminal + thermal fuse) incl. cable entry clamp with stress relief 
Mounting bracket long (optional)
Allows greater tilt of the sound column; Dimensions:
18.5 x 13.5 cm
  Ceramic terminal
(optional)
 

 




Installation, Operation, Maintenance
To avoid injury or damage, always make sure to mount the speakers securely.
Make sure that all amplifiers are switched of and all controls are turned down before connecting the speaker systems.
Please pay attention on the connection to the transformer board and make sure that the polarity of the speakers is correct (also at the amplifier).
After connecting all systems cross-check the wiring with a phase checker. Make sure that the rated sum power of the speakers do not exceed the output power of the 100 V amplifier!
Do not open the loudspeaker during operation.

Fix the rigid or swing and tilt bracket onto wanted position.
Unscrew the 4 fixing screws of the speaker grille, on the top and bottom lid and remove the grille.
Remove the metal plate, which is covering the connection terminal (2 screws).
Lead cable trough the cable gland and connect to terminal (100/50/25/12,5 W).
Fasten the connection terminal cover and fix the speaker with two M6 scews into the thread inserts. Screw in the 4 fixing scews for the speaker grille.
For optimum performance, always use the correct voltage, power and operate within the frequency limits as specified.




Subject to technical changes


 Downloads


NeodymLine_WP_5424_Prospekt



  News
28.03.2013   Prolight+Sound 2013
06.06.2012   Die neue Smart-Box
23.04.2012   EN 54-24 zertifizierte...
09.01.2012   NeoFocus
27.10.2011   1. Platz bei „Trio des Jahres“ geht an ITEC
  Referenzen und Projekte
» Säle und Hallen
» Kirchen/Österreich
» Kirchen/Deutschland
» Kirchen/Andere Länder
» Sportstätten/Stadien
» Außenbeschallungen
» Mobile Tonanlagen
» Seminarraumtechnik
  Preisliste / Referenzliste
» Preisliste anfordern
» Referenzliste anfordern

Zertifiziert nach
ISO 9001:2008