| ITEC NEODYMLINE 4/100V/WP/54-24 |

|
| Enviromental Type: |
B |
| Termination |
Inside screw terminal |
| Rated Noise Voltage: |
100V |
| Rated Noise Power: |
50 W |
| Power Setting: |
50 / 25 / 12,5 / 6,25 W |
| Driver: |
4 x 3“ cone neodymium |
| Weight |
3,7 kg |
| Dimensions (WxHxD): |
100 x 602 x 100 mm |
| IP-rating |
min 33 |
| Material/Color |
welded aluminium / powder coated RAL
9010, RAL 9011 or customized |
| Mounting |
powder coated rigid bracket /
swing and tilt bracket |
Sensitivity for the stated
reference axis: |
79 dB (Pink noise total 1W/4 Meters) |
Maximum sound
pressure level: |
95 dB (Pink noise total 50W/4 Meters) |
|
- 2-way high-power column loudspeaker system loaded with 4x3“ neodymium transducers
- passive crossover network unit
- Highest sound pressures even at very small dimensions
- Perfect sound in acoustically challenging areas
- Perfect speech intelligibility in reverberant room
- Integrated power switch (50 / 25 / 12,5 / 6,25 W)
|
|
The ITEC NeodymLine 4 is a 2-way high-power passive column loudspeaker system with best performance in respect of speech intelligibility and music reproduction in difficult conditions.
Due to the placement of the 4x3“ nodymium transducers and frequency crossover, the vertical pattern is perfect even for reverberant rooms - less reflections onto ceilings.
Developed for areas of public life, where security is the highest bid Certified quality assurance ensuring consistent performance at continuous operation for decades. The optical integration of the NeodymLine - Series is very simply, because of the slim and elegant design. The build in 50 VA Tranformer provides high quality audio performance.
Fields of application: airports, railway stations, malls, industrial buildings, architetural buildings (glass), house of worship, conference rooms, historical building, etc.
|
|
| Acoustical measurement enviroment: |
free field |
Frequency response for each stated reference axis:
(Sensitivity 100Hz-10kHz 1/3 Oct. Pink noise total 1W/4 Meters) |
| frequency |
dB |
frequency |
dB |
frequency |
dB |
| 100 Hz |
55 |
125 Hz |
54 |
160 Hz |
64 |
| 200 Hz |
61 |
250 Hz |
66 |
315 |
67 |
| 400 Hz |
69 |
500 Hz |
66 |
630 |
66 |
| 800 Hz |
63 |
1000 Hz |
67 |
1250 |
67 |
| 1600 Hz |
65 |
2000 Hz |
66 |
2500 |
65 |
| 3150 Hz |
65 |
4000 Hz |
63 |
5000 |
63 |
| 6300 Hz |
64 |
8000 Hz |
66 |
10000 |
67 |
| |
|
|
|
|
|
| Horizontal / Vertical coverage angles: |
| frequency |
horizontal |
vertical |
|
|
|
| 500 Hz |
360 |
142 |
|
|
|
| 1 kHz |
198 |
113 |
|
|
|
| 2 kHz |
169 |
34 |
|
|
|
| 4 kHz |
201 |
22 |
|
|
|
| |
|
|
|
|
|
| Rated impedance for each tapping: |
| Power |
Impedance |
|
|
|
|
| 50 W |
200 Ω |
|
|
|
|
| 25 W |
400 Ω |
|
|
|
|
| 12,5 W |
800 Ω |
|
|
|
|
| 6,25 W |
1600 Ω |
|
|
|
|
|
|
|
|
| Mounting accessories |
Terminal |
 |
Mounting bracket standard (short)
Dimensions:
9 x 6.5 cm |
 |
Terminal (standard) Connection terminal covered by metal plate (Ceramic Terminal + thermal fuse) incl. cable entry clamp with stress relief |
 |
Mounting bracket long (optional)
Allows greater tilt of the sound column; Dimensions:
18.5 x 13.5 cm |
|
Ceramic terminal
(optional) |
 |
Swing & tilt mounting (optional)
black/white |
|
|
|
|

Installation, Operation, Maintenance
To avoid injury or damage, always make sure to mount the speakers securely.
Make sure that all amplifiers are switched of and all controls are turned down before connecting the speaker systems.
Please pay attention on the connection to the transformer board and make sure that the polarity of the speakers is correct (also at the amplifier).
After connecting all systems cross-check the wiring with a phase checker. Make sure that the rated sum power of the speakers do not exceed the output power of the 100 V amplifier!
Do not open the loudspeaker during operation.
Fix the rigid or swing and tilt bracket onto wanted position.
Unscrew the 4 fixing screws of the speaker grille, on the top and bottom lid and remove the grille.
Remove the metal plate, which is covering the connection terminal (2 screws).
Lead cable trough the cable gland and connect to terminal (50/25/12,5/6,25 W).
Fasten the connection terminal cover and fix the speaker with two M6 scews into the thread inserts. Screw in the 4 fixing scews for the speaker grille.
For optimum performance, always use the correct voltage, power and operate within the frequency limits as specified.
|
| ITEC NEODYMLINE 8/100V/WP/54-24 |

|
| Enviromental Type: |
B |
| Termination |
Inside screw terminal |
| Rated Noise Voltage: |
100V |
| Rated Noise Power: |
50 W |
| Power Setting: |
50 / 25 / 12,5 / 6,25 W |
| Driver: |
8 x 3“ cone neodymium |
| Weight |
5,4 kg |
| Dimensions (WxHxD): |
100 x 967 x 100 mm |
| IP-rating |
min 33 |
| Material/Color |
welded aluminium / powder coated RAL
9010, RAL 9011 or customized |
| Mounting |
powder coated rigid bracket /
swing and tilt bracket |
Sensitivity for the stated
reference axis: |
81 dB (Pink noise total 1W/4 Meters) |
Maximum sound
pressure level: |
98 dB (Pink noise total 50W/4 Meters) |
|
- 2-way high-power column loudspeaker system loaded with 8x3“ neodymium transducers
- passive crossover network unit
- Highest sound pressures even at very small dimensions
- Perfect sound in acoustically challenging areas
- Perfect speech intelligibility in reverberant room
- Integrated power switch (50 / 25 / 12,5 / 6,25 W) |
|
The ITEC NeodymLine 8 is a 2-way high-power passive column loudspeaker system with best performance in respect of speech intelligibility and music reproduction in difficult conditions.
Due to the placement of the 8x3“ nodymium transducers and frequency crossover, the vertical pattern is perfect even for reverberant rooms - less reflections onto ceilings.
Developed for areas of public life, where security is the highest bid Certified quality assurance ensuring consistent performance at continuous operation for decades. The optical integration of the NeodymLine - Series is very simply, because of the slim and elegant design. The build in 50 VA Tranformer provides high quality audio performance.
Fields of application: airports, railway stations, malls, industrial buildings, architetural buildings (glass), house of worship, conference rooms, historical building, etc.
|
|
| Acoustical measurement enviroment: |
free field |
Frequency response for each stated reference axis:
(Sensitivity 100Hz-10kHz 1/3 Oct. Pink noise total 1W/4 Meters) |
| frequency |
dB |
frequency |
dB |
frequency |
dB |
| 100 Hz |
59 |
125 Hz |
57 |
160 Hz |
67 |
| 200 Hz |
65 |
250 Hz |
70 |
315 |
70 |
| 400 Hz |
70 |
500 Hz |
69 |
630 |
66 |
| 800 Hz |
68 |
1000 Hz |
69 |
1250 |
68 |
| 1600 Hz |
68 |
2000 Hz |
69 |
2500 |
69 |
| 3150 Hz |
67 |
4000 Hz |
66 |
5000 |
63 |
| 6300 Hz |
64 |
8000 Hz |
66 |
10000 |
67 |
| |
|
|
|
|
|
| Horizontal / Vertical coverage angles: |
| frequency |
horizontal |
vertical |
|
|
|
| 500 Hz |
360 |
71 |
|
|
|
| 1 kHz |
316 |
47 |
|
|
|
| 2 kHz |
168 |
28 |
|
|
|
| 4 kHz |
185 |
16 |
|
|
|
| |
|
|
|
|
|
| Rated impedance for each tapping: |
| Power |
Impedance |
|
|
|
|
| 50 W |
200 Ω |
|
|
|
|
| 25 W |
400 Ω |
|
|
|
|
| 12,5 W |
800 Ω |
|
|
|
|
| 6,25 W |
1600 Ω |
|
|
|
|
|
|
|
|
| Mounting accessories |
Terminal |
 |
Mounting bracket standard (short)
Dimensions:
9 x 6.5 cm |
 |
Terminal (standard) Connection terminal covered by metal plate (Ceramic Terminal + thermal fuse) incl. cable entry clamp with stress relief |
 |
Mounting bracket long (optional)
Allows greater tilt of the sound column; Dimensions:
18.5 x 13.5 cm |
|
Ceramic terminal
(optional) |
 |
Swing & tilt mounting (optional)
black/white |
|
|
|
|

Installation, Operation, Maintenance
To avoid injury or damage, always make sure to mount the speakers securely.
Make sure that all amplifiers are switched of and all controls are turned down before connecting the speaker systems.
Please pay attention on the connection to the transformer board and make sure that the polarity of the speakers is correct (also at the amplifier).
After connecting all systems cross-check the wiring with a phase checker. Make sure that the rated sum power of the speakers do not exceed the output power of the 100 V amplifier!
Do not open the loudspeaker during operation.
Fix the rigid or swing and tilt bracket onto wanted position.
Unscrew the 4 fixing screws of the speaker grille, on the top and bottom lid and remove the grille.
Remove the metal plate, which is covering the connection terminal (2 screws).
Lead cable trough the cable gland and connect to terminal (50/25/12,5/6,25 W).
Fasten the connection terminal cover and fix the speaker with two M6 scews into the thread inserts. Screw in the 4 fixing scews for the speaker grille.
For optimum performance, always use the correct voltage, power and operate within the frequency limits as specified.
|
| ITEC NEODYMLINE 16/100V/WP/54-24 |

|
| Enviromental Type: |
B |
| Termination |
Inside screw terminal |
| Rated Noise Voltage: |
100V |
| Rated Noise Power: |
100 W |
| Power Setting: |
100 / 25 / 12,5 / 6,25 W |
| Driver: |
16 x 3“ cone neodymium |
| Weight |
10,8 kg |
| Dimensions (WxHxD): |
100 x 1918 x 100 mm |
| IP-rating |
min 33 |
| Material/Color </td>
| welded aluminium / powder coated RAL
9010, RAL 9011 or customized |
| Mounting |
powder coated rigid bracket /
swing and tilt bracket |
Sensitivity for the stated
reference axis: |
82 dB (Pink noise total 1W/4 Meters) |
Maximum sound
pressure level: |
101 dB (Pink noise total 50W/4 Meters) |
|
- 4-way high-power column loudspeaker system loaded with 16x3“ neodymium transducers
- passive crossover network unit
- Highest sound pressures even at very small dimensions
- Perfect sound in acoustically challenging areas
- Perfect speech intelligibility in reverberant room
- Integrated power switch (100 / 50 / 25 / 12,5 W) |
|
The ITEC NeodymLine 16 is a 4-way high-power passive column loudspeaker system with best performance in respect of speech intelligibility and music reproduction in difficult conditions.
Due to the placement of the 16x3“ nodymium transducers and frequency crossover, the vertical pattern is perfect even for reverberant rooms - less reflections onto ceilings.
Developed for areas of public life, where security is the highest bid Certified quality assurance ensuring consistent performance at continuous operation for decades. The optical integration of the NeodymLine - Series is very simply, because of the slim and elegant design. The build in 100 VA Tranformer provides high quality audio performance.
Fields of application: airports, railway stations, malls, industrial buildings, architetural buildings (glass), house of worship, conference rooms, historical building, etc.
|
|
| Acoustical measurement enviroment: |
free field |
Frequency response for each stated reference axis:
(Sensitivity 100Hz-10kHz 1/3 Oct. Pink noise total 1W/4 Meters) |
| frequency |
dB |
frequency |
dB |
frequency |
dB |
| 100 Hz |
61 |
125 Hz |
60 |
160 Hz |
66 |
| 200 Hz |
64 |
250 Hz |
70 |
315 |
72 |
| 400 Hz |
77 |
500 Hz |
71 |
630 |
69 |
| 800 Hz |
68 |
1000 Hz |
71 |
1250 |
70 |
| 1600 Hz |
70 |
2000 Hz |
70 |
2500 |
70 |
| 3150 Hz |
67 |
4000 Hz |
65 |
5000 < |
62 |
| 6300 Hz |
64 |
8000 Hz |
66 |
10000 |
66 |
| |
|
|
|
|
|
| Horizontal / Vertical coverage angles: |
| frequency |
horizontal |
vertical |
|
|
|
| 500 Hz |
360 |
92 |
|
|
|
| 1 kHz |
314 |
41 |
|
|
|
| 2 kHz |
145 |
23 |
|
|
|
| 4 kHz |
179 |
18 |
|
|
|
| |
|
|
|
|
|
| Rated impedance for each tapping: |
| Power |
Impedance |
|
|
|
|
| 100 W |
100 Ω |
|
|
|
|
| 50 W |
200 Ω |
|
|
|
|
| 25 W |
400 Ω |
|
|
|
|
| 12,5 W |
800 Ω |
|
|
|
|
|
|
|
|
| Mounting accessories |
Terminal |
 |
Mounting bracket standard (short)
Dimensions:
9 x 6.5 cm |
 |
Terminal (standard) Connection terminal covered by metal plate (Ceramic Terminal + thermal fuse) incl. cable entry clamp with stress relief |
 |
Mounting bracket long (optional)
Allows greater tilt of the sound column; Dimensions:
18.5 x 13.5 cm |
|
Ceramic terminal
(optional) |
|
|

Installation, Operation, Maintenance
To avoid injury or damage, always make sure to mount the speakers securely.
Make sure that all amplifiers are switched of and all controls are turned down before connecting the speaker systems.
Please pay attention on the connection to the transformer board and make sure that the polarity of the speakers is correct (also at the amplifier).
After connecting all systems cross-check the wiring with a phase checker. Make sure that the rated sum power of the speakers do not exceed the output power of the 100 V amplifier!
Do not open the loudspeaker during operation.
Fix the rigid or swing and tilt bracket onto wanted position.
Unscrew the 4 fixing screws of the speaker grille, on the top and bottom lid and remove the grille.
Remove the metal plate, which is covering the connection terminal (2 screws).
Lead cable trough the cable gland and connect to terminal (100/50/25/12,5 W).
Fasten the connection terminal cover and fix the speaker with two M6 scews into the thread inserts. Screw in the 4 fixing scews for the speaker grille.
For optimum performance, always use the correct voltage, power and operate within the frequency limits as specified.
Subject to technical changes
|
|
 |

|
|